MB85RC16
■ POWER ON SEQUENCE
tpd
tf
tOFF
tr
tp u
V DD
2.7 V
V IH (Min)
1.0 V
V IL (Max)
0 V
V DD
2.7 V
V IH (Min)
1.0 V
V IL (Max)
0 V
SDA, SCL
SDA, SCL > V DD × 0. 8 *
SDA, SCL : Don ' t care
SDA, SCL > V DD × 0. 8 *
SDA, SCL
* : SDA, SCL (Max) < V DD + 0.5 V
Parameter
SDA, SCL level hold time during power down
SDA, SCL level hold time during power up
Power supply rise time
Power supply fall time
Power off time
Symbol
tpd
tpu
tr
tf
tOFF
Min
85
85
0.01
0.01
50
Value
Max
?
?
50
50
?
Unit
ns
ns
ms
ms
ms
■ NOTES ON USE
? Data written before performing IR reflow is not guaranteed after IR reflow.
? V DD is required to be rising from 0 V because turning the power on from an intermediate level may cause
malfunctions, when the power is turned on.